5820 Series - Mortise
5820S Panic-Rated Mortise Lock Exit Device
5820F Fire-Rated Mortise Lock Exit Device
5820 series are mortise lock exit devices to be used on single doors or pairs of doors. It is designed for heavy duty commercial applications, such as train stations, airports, office buildings, schools, and medical facilities that extra security is required. 5820 series are available in a variety of finishes to match any design style.
Certifications
UL Listed: UL listed as Panic Exit Hardware or 3-hour Fire Exit Hardware
ASNI Certified: Devices are ANSI A156.3-2008, Grade 1
Applications
- Non-handed design for easy installation
- 5820S mortise lock exit devices are used for all types of single and double doors
- 5820F mortise lock exit devices are used for UL listed fire labeled single doors up to 4’ x 8’ (1219mm x 2438mm) or 8’ x 8’ (2438mm x 2438mm) double doors installations
- The exit devices are available in the following finishes: US3, US4,US10, US10B, US26, US26D and US32D
- Designed for wide stile doors
- High shock-resistant latching mechanical design for protection from vandalism
- All inside components are made of high rust-resistant alloy or heavily electroplated steel, no corrosion is concerned
- Baked powder coating, electroplated, or architectural base material finish on all exposed surfaces are available for users choice
Device Lengths: Short (36"): 33-15/32" (850mm),
Long (48"): 44-3/4" (1137mm)
Door Widths: 36" - For 29" to 36" (736mm to 914mm) door size
48" - For 33" to 48" (838mm to 1219mm) door size
Minimum Stile Width: 4-1/4" (107mm)
Latch Bolt: Stainless Steel Two-piece mechanical 3/4" (19mm) with anti-friction insert and auxiliary deadlocking latch
Strikes: Universal curved lip, non-handed, 818 (panic), 828 (fire), Optional 831 (panic) or 832 (fire) flat ANSI Strike for door pairs with overlapping astragal (7/8" lip)
Dogging Kit: Panic device - Hex key dogging (RD) standard
Fire device - No mechanical dogging (ND)
Dogging Options: Cylinder Dogging (CD)
Less Dogging (LD)
Mounting Fasteners: Panic device - machine screws furnished standard
Fire device - Sex nuts and bolts (SNB) supplied standard
SNB are required to use for wood doors, order SNB separately
Mounting Height: Device centerline from finished floor is 40" (1016mm) standard
Projection: Push bar Neutral: 3-1/16" (78mm)
Push bar Depressed: 2-19/32" (66mm)